SUN HYDRAULICS
SQFBJEV
$143.96 USD
- SUN HYDRAULICS
- Material:SQFBJEV
- Model:SQFB-JEV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBJEV (SQFBJEV) is a kickdown sequence valve designed to open completely and maintain an open state when the inlet port 1 pressure surpasses the valve setting, enabling unrestricted flow from port 1 to port 2. This occurs as long as the pressure at port 1 exceeds that of port 2. To reset, the pressure at port 1 must drop below the valve setting, flow from port 1 to port 2 must halt, and pressure at port 2 should be equal to or greater than that at port 1. The valve features a main stage orifice protected by a stainless steel screen and should not be used in load-holding applications. It is intended for actuator-side use in systems where flow cessation through the valve is required for resetting; if used on the pump side, pump flow must be stopped for resetting. The design incorporates Sun Hydraulics' floating style construction to minimize internal part binding due to excessive installation torque or machining variations. With a capacity of 30 gpm (120 L/min) and a maximum operating pressure of 5000 psi (350 bar), it has a typical response time of 25 ms and minimal leakage. The adjustment involves up to five clockwise turns to increase settings, with specific hex sizes and torque requirements for installation and adjustments. The model weighs approximately .50 lb (0.25 kg) and uses Viton seals for its cartridge seal kit.
The Sun Hydraulics SQFBJEV (SQFBJEV) is a kickdown sequence valve designed to open completely and maintain an open state when the inlet port 1 pressure surpasses the valve setting, enabling unrestricted flow from port 1 to port 2. This occurs as long as the pressure at port 1 exceeds that of port 2. To reset, the pressure at port 1 must drop below the valve setting, flow from port 1 to port 2 must halt, and pressure at port 2 should be equal to or greater than that at port 1. The valve features a main stage orifice protected by a stainless steel screen and should not be used in load-holding applications. It is intended for actuator-side use in systems where flow cessation through the valve is required for resetting; if used on the pump side, pump flow must be stopped for resetting. The design incorporates Sun Hydraulics' floating style construction to minimize internal part binding due to excessive installation torque or machining variations. With a capacity of 30 gpm (120 L/min) and a maximum operating pressure of 5000 psi (350 bar), it has a typical response time of 25 ms and minimal leakage. The adjustment involves up to five clockwise turns to increase settings, with specific hex sizes and torque requirements for installation and adjustments. The model weighs approximately .50 lb (0.25 kg) and uses Viton seals for its cartridge seal kit.
Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Should not be used in load holding applications.
- The main stage orifice is protected by a 150 micron stainless steel screen.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Factory Pressure Settings Established at | Kick down pointKick down point |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 25 ms25 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.50 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .50 lb0,25 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
Notes: