You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQFBKAV


$157.85 USD
  • SUN HYDRAULICS
  • Material:SQFBKAV
  • Model:SQFB-KAV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBKAV (SQFBKAV) is a specialized kickdown sequence valve designed to open completely and maintain an unrestricted flow path from port 1 to port 2 once the inlet pressure exceeds the valve's setting. This mechanism ensures efficient fluid management, particularly when used on the actuator side of a hydraulic system. The valve remains open as long as the pressure at port 1 is greater than at port 2, and it resets only when these conditions are reversed. It features a main stage orifice protected by a 150-micron stainless steel screen, ensuring durability and reliability in high-pressure environments up to 5000 psi (350 bar). The valve incorporates Sun\u2019s floating style construction, which minimizes internal binding due to installation torque or machining variations. With a capacity of 30 gpm (120 L/min) and a typical response time of 25 ms, it is suitable for applications requiring quick actuation. Note that this valve should not be used in load-holding applications due to its specific operational characteristics. Installation requires careful adherence to specified torque values, with an installation torque between 45-50 lbf ft (61-68 Nm). The adjustment screw features an internal hex size of 5/32 inches (4 mm), allowing precise control over the pressure settings with up to five clockwise turns available for adjustment. The SQFBKAV model offers robust performance with minimal leakage, making it ideal for high-demand hydraulic systems where reliable sequencing is critical.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.