You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQFBLDV


$145.94 USD
  • SUN HYDRAULICS
  • Material:SQFBLDV
  • Model:SQFB-LDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBLDV (SQFBLDV) is a highly specialized kickdown sequence valve designed for precise hydraulic control applications. This valve operates by kicking completely open and maintaining an unrestricted flow path from port 1 to port 2 once the inlet pressure surpasses the preset threshold, with the setting being relative to the drain port 3. It remains open as long as the pressure at port 1 exceeds that at port 2. To reset, conditions must be met where the pressure at port 1 falls below its setting, flow ceases between ports, and pressure at port 2 is equal to or greater than that at port 1. Notably, this valve should not be utilized in load-holding scenarios. The SQFBLDV features a robust design incorporating Sun\u2019s floating style construction, minimizing internal part binding due to installation torque or machining variations. It is protected by a stainless steel screen over the main stage orifice and supports a maximum operating pressure of 5000 psi (350 bar). The valve\u2019s response time is typically around 25 ms, with minimal leakage rates. It can handle capacities up to 30 gpm (120 L/min), making it suitable for high-flow requirements. This model is interchangeable with other three-port sequence cartridges of similar frame sizes, ensuring flexibility in application setups. It\u2019s intended for use on the actuator side of hydraulic systems where flow cessation is necessary for resetting; if applied on the pump side, pump flow must also be halted for reset functionality. Installation specifics include a hex size of 1-1/8 inches and requires precise torque settings during installation and adjustment processes to ensure optimal performance.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.