***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBLNN (SQFBLNN) is a kickdown sequence valve designed to deliver an unrestricted flow path from port 1 to port 2 once the pressure at inlet port 1 exceeds the valve's setting. This valve is particularly suited for applications where it is positioned on the actuator side of a hydraulic system, as flow through the valve must stop for it to reset. It features a unique floating style construction that minimizes internal part binding due to excessive installation torque or machining variations. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability in operation. With a maximum operating pressure of 5000 psi (350 bar) and a capacity of 30 gpm (120 L/min), this sequence valve provides robust performance under demanding conditions. The response time is typically around 25 milliseconds, and it maintains minimal leakage with a maximum valve leakage at 110 SUS (24 cSt) of just 3 in\u00b3/min (50 cc/min). The SQFBLNN model incorporates adjustable settings with five clockwise turns needed to increase the setting, and it includes specific torque requirements for installation and adjustment components such as the locknut and adjustment screw. This valve should not be used in load-holding applications due to its design characteristics. It also features interchangeable physical and functional attributes with other three-port sequence cartridges, ensuring compatibility within its series frame size.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006