***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBLNV (Material Number: SQFBLNV) is a kickdown sequence valve designed to open completely and maintain an unrestricted flow path from port 1 to port 2 once the inlet pressure surpasses the valve setting. This valve is engineered for use on the actuator side of hydraulic systems, where flow through the valve must cease for it to reset. It should not be used in load-holding applications. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and performance reliability. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio, with a maximum allowable pressure of 5000 psi (350 bar). Featuring Sun's floating style construction, this valve minimizes internal binding risks due to installation torque or machining variations. The SQFBLNV model offers a capacity of up to 30 gpm (120 L/min) with factory pressure settings established at the kickdown point. Its maximum operating pressure reaches up to 5000 psi (350 bar), with typical response times around 25 milliseconds. The valve exhibits minimal leakage, capped at 3 in\u00b3/min (50 cc/min) at 110 SUS (24 cSt). Installation requires specific torque values: valve hex size is 1-1/8 inches (28.6 mm), with an installation torque range of 45-50 lbf-ft (61-68 Nm). Adjustment screw internal hex size is set at 5/32 inches (4 mm), while locknut hex size is specified as 9/16 inches (15 mm) with a locknut torque range of 80-90 lbf-in (9-10 Nm). The model weighs approximately .50 lb (.25 kg) and uses Viton seal kits for enhanced performance and longevity under various conditions.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006