***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBMAV (SQFBMAV) is a kickdown sequence valve designed to create an unrestricted flow path from port 1 to port 2 once the pressure at the inlet port 1 exceeds the valve setting. This mechanism ensures that the valve remains open as long as the pressure at port 1 surpasses that of port 2. To reset, the pressure at port 1 must drop below the valve setting, and flow must cease between ports 1 and 2, with pressure at port 2 equal to or greater than that at port 1. Notably, this valve should not be used in load holding applications. It features a protected main stage orifice with a 150-micron stainless steel screen and can handle pressures up to a maximum of 5000 psi (350 bar). The design incorporates Sun's floating style construction, reducing risks of internal binding due to installation torque or machining variations. The SQFBMAV is intended for use on the actuator side of systems; if used on the pump side, pump flow must cease for resetting. It offers a capacity of up to 30 gpm (120 L/min) and has a typical response time of about 25 ms. The valve's leakage is minimal, with a maximum of approximately 3 in\u00b3/min (50 cc/min) under specified conditions. Installation requires specific torques for both the valve and locknut, ensuring secure placement within hydraulic systems. Additionally, it includes an adjustment feature allowing for fine-tuning via clockwise turns to increase settings, accommodating various operational needs in hydraulic applications.
The Sun Hydraulics SQFBMAV (SQFBMAV) is a kickdown sequence valve designed to create an unrestricted flow path from port 1 to port 2 once the pressure at the inlet port 1 exceeds the valve setting. This mechanism ensures that the valve remains open as long as the pressure at port 1 surpasses that of port 2. To reset, the pressure at port 1 must drop below the valve setting, and flow must cease between ports 1 and 2, with pressure at port 2 equal to or greater than that at port 1. Notably, this valve should not be used in load holding applications. It features a protected main stage orifice with a 150-micron stainless steel screen and can handle pressures up to a maximum of 5000 psi (350 bar). The design incorporates Sun's floating style construction, reducing risks of internal binding due to installation torque or machining variations. The SQFBMAV is intended for use on the actuator side of systems; if used on the pump side, pump flow must cease for resetting. It offers a capacity of up to 30 gpm (120 L/min) and has a typical response time of about 25 ms. The valve's leakage is minimal, with a maximum of approximately 3 in\u00b3/min (50 cc/min) under specified conditions. Installation requires specific torques for both the valve and locknut, ensuring secure placement within hydraulic systems. Additionally, it includes an adjustment feature allowing for fine-tuning via clockwise turns to increase settings, accommodating various operational needs in hydraulic applications.
Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Should not be used in load holding applications.
- The main stage orifice is protected by a 150 micron stainless steel screen.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Factory Pressure Settings Established at | Kick down pointKick down point |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 25 ms25 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.50 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .50 lb0,25 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.