You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQFBMNN


$141.97 USD
  • SUN HYDRAULICS
  • Material:SQFBMNN
  • Model:SQFB-MNN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBMNN (SQFBMNN) is a kickdown sequence valve designed to optimize hydraulic systems by providing an unrestricted flow path from port 1 to port 2 once the pressure at the inlet port exceeds the valve setting. This valve remains open as long as the pressure at port 1 is greater than at port 2, requiring a reset by reducing pressure and ceasing flow from port 1 to port 2. Notably, this model should not be used in load-holding applications due to its design characteristics. It features a main stage orifice protected by a 150-micron stainless steel screen and has a maximum operating pressure of 5000 psi (350 bar). The valve's response time is typically around 25 ms, with minimal leakage of up to 3 in\u00b3/min (50 cc/min) at specified conditions. The adjustment mechanism allows for precise control with up to five clockwise turns to increase settings, supported by robust construction that minimizes internal binding risks. The valve's physical attributes include a hex size of 1-1/8 inches and an installation torque range of 45-50 lbf\u00b7ft (61-68 Nm). Additionally, it incorporates Sun's floating style construction for enhanced reliability under varying installation conditions. Weighing just .50 lb (.25 kg), it is compact yet efficient, making it suitable for use on the actuator side of hydraulic systems where flow cessation is necessary for resetting.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.