***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBONN (SQFBONN) is a kickdown sequence valve designed for hydraulic systems where the valve will kick completely open and remain open once the inlet port pressure exceeds the valve setting. This creates an unrestricted flow path from port 1 to port 2, with the pressure setting at port 1 being relative to the drain port 3. The valve stays open as long as the pressure at port 1 exceeds that at port 2. To reset, pressure at port 1 must fall below the valve's setting, flow from port 1 to port 2 must stop, and pressure at port 2 must be equal to or greater than that at port 1. Notably interchangeable with other three-port sequence cartridges, this model should not be used in load holding applications. It features a main stage orifice protected by a 150-micron stainless steel screen and incorporates Sun's floating style construction for reduced internal part binding risks. The maximum operating pressure reaches up to 5000 psi (350 bar), with a capacity of handling flows up to 30 gpm (120 L/min). The response time is typically around 25 ms, and maximum leakage is minimal at specified conditions. Installation requires a torque of between 45-50 lbf\u00b7ft (61-68 Nm), and adjustments can be made via an internal hex screw. Seal kit options are available in Viton material for cartridge maintenance.
The Sun Hydraulics SQFBONN (SQFBONN) is a kickdown sequence valve designed for hydraulic systems where the valve will kick completely open and remain open once the inlet port pressure exceeds the valve setting. This creates an unrestricted flow path from port 1 to port 2, with the pressure setting at port 1 being relative to the drain port 3. The valve stays open as long as the pressure at port 1 exceeds that at port 2. To reset, pressure at port 1 must fall below the valve's setting, flow from port 1 to port 2 must stop, and pressure at port 2 must be equal to or greater than that at port 1. Notably interchangeable with other three-port sequence cartridges, this model should not be used in load holding applications. It features a main stage orifice protected by a 150-micron stainless steel screen and incorporates Sun's floating style construction for reduced internal part binding risks. The maximum operating pressure reaches up to 5000 psi (350 bar), with a capacity of handling flows up to 30 gpm (120 L/min). The response time is typically around 25 ms, and maximum leakage is minimal at specified conditions. Installation requires a torque of between 45-50 lbf\u00b7ft (61-68 Nm), and adjustments can be made via an internal hex screw. Seal kit options are available in Viton material for cartridge maintenance.
Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Should not be used in load holding applications.
- The main stage orifice is protected by a 150 micron stainless steel screen.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Factory Pressure Settings Established at | Kick down pointKick down point |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 25 ms25 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.50 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .50 lb0,25 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.