SUN HYDRAULICS
SXCBCBN
$105.04 USD
- SUN HYDRAULICS
- Material:SXCBCBN
- Model:SXCB-CBN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SXCBCBN (Material Number: SXCBCBN) is an atmospherically referenced, direct-acting sequence valve designed to supply a secondary circuit with flow once the pressure at inlet port 1 exceeds the valve setting. This sequence valve controls the pressure at port 1 relative to the atmospheric vent, making it suitable for use in load holding applications where a drain connection is not possible. The valve incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. With a cavity size of T-13A and a capacity of 15 gpm (60 L/min), it features factory pressure settings established at 2 in/min (30 cc/min) and can withstand a maximum operating pressure of 5000 psi (350 bar). The typical response time is 2 ms, and it exhibits maximum valve leakage at reseat of 10 drops/min (0.7 cc/min). Adjustments are made by turning clockwise up to four turns to increase the setting, with specific torque requirements for installation and locknut adjustments. The model weighs approximately .30 lb (0.15 kg) and comes with a Viton seal kit available under part number 990010006. It is important to note that atmospherically referenced valves may leak externally or allow moisture into the spring chamber over time, with about one drop (0.07 cc) of fluid passing into the vented spring chamber every 4000 cycles.
The Sun Hydraulics SXCBCBN (Material Number: SXCBCBN) is an atmospherically referenced, direct-acting sequence valve designed to supply a secondary circuit with flow once the pressure at inlet port 1 exceeds the valve setting. This sequence valve controls the pressure at port 1 relative to the atmospheric vent, making it suitable for use in load holding applications where a drain connection is not possible. The valve incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. With a cavity size of T-13A and a capacity of 15 gpm (60 L/min), it features factory pressure settings established at 2 in/min (30 cc/min) and can withstand a maximum operating pressure of 5000 psi (350 bar). The typical response time is 2 ms, and it exhibits maximum valve leakage at reseat of 10 drops/min (0.7 cc/min). Adjustments are made by turning clockwise up to four turns to increase the setting, with specific torque requirements for installation and locknut adjustments. The model weighs approximately .30 lb (0.15 kg) and comes with a Viton seal kit available under part number 990010006. It is important to note that atmospherically referenced valves may leak externally or allow moisture into the spring chamber over time, with about one drop (0.07 cc) of fluid passing into the vented spring chamber every 4000 cycles.
Atmospherically referenced, direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.
- Suitable for use in load holding applications.
- Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
- Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 15 gpm60 L/min. |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 2 ms2 ms |
| Maximum Valve Leakage at Reseat | 10 drops/min.0,7 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 44 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-010-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions