***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SXCBLWV (SXCBLWV) is an atmospherically referenced, direct-acting sequence valve designed to supply a secondary circuit with flow once the inlet port pressure exceeds the valve setting. This sequence valve maintains pressure at port 1 relative to the atmospheric vent, making it suitable for load holding applications where a drain connection is not feasible. However, it is important to note that these valves may leak externally or allow moisture into the spring chamber over time, with approximately one drop (0.07 cc) of fluid entering the vented spring chamber every 4000 cycles. The valve incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. The SXCBLWV features a T-13A cavity and series 1 capacity of up to 15 gpm (60 L/min), with factory pressure settings established at 2 in/min (30 cc/min). It can handle a maximum operating pressure of 5000 psi (350 bar) and has a typical response time of 2 ms. The maximum valve leakage at reseat is specified at 10 drops/min (0.7 cc/min). The adjustment mechanism allows for increasing the setting with 44 clockwise turns, and it includes a valve hex size of 7/8 in. (22.2 mm) and an installation torque range of 30-35 lbf ft (41-47 Nm). The adjustment screw has an internal hex size of 5/32 in. (4 mm), and the locknut features a hex size of 9/16 in. (15 mm) with a torque specification of 80-90 lbf in. (9-10 Nm). This model weighs approximately .30 lb (.15 kg) and utilizes Viton seal kits for cartridge sealing requirements.

Atmospherically referenced, direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.

  • Suitable for use in load holding applications.
  • Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
  • Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-13A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at2 in³/min.30 cc/min.
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical2 ms2 ms
Maximum Valve Leakage at Reseat10 drops/min.0,7 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting44
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ